Tuya TRV602
Tuya devices may be sold under a white-label brand by other companies.
This page explains how to configure a Tuya TRV thermostat using the Zigbee protocol. With a Tuya gateway, you can use Tuya WIFI integration.
WARNING
This device is NOT recommanded for VTherm. It is unstable and require somme automation to work.
Required automation
You need to add the following automation. Change the triggers entity IDs with yours IDs.
alias: "TRV: Erzwinge Manual Modus (Garderobe & Gästezimmer)"
description: Zwingt TRVs auf manual, außer wenn sie explizit ausgeschaltet sind
triggers:
- entity_id:
- climate.eg_garderobe
- climate.eg_gaestezimmer
attribute: preset_mode
trigger: state
conditions:
- condition: template
value_template: >
{% set current_preset = state_attr(trigger.entity_id, 'preset_mode') %} {{
current_preset not in ['manual', 'off'] and current_preset is not none }}
actions:
- target:
entity_id: "{{ trigger.entity_id }}"
action: climate.set_preset_mode
data:
preset_mode: manual
Gerätekonfiguration
Initialisierung
Gehe zu Einstellungen, dann zu Integrationen und dort "neue Integration hinzufügen" anklicken. Suche nach Versatile Thermostat.
Klicken auf VTherm auf Thermostat.
Grundeinstellungen
Gehe zum Abschnitt "Hauptattribute".
- Wähle einen Namen für das Thermostat
- Stelle den Temperatursensor des Raumes ein
- Wenn das Zigbee-Protokoll verwendet wird und eine "last_seen"-Entität für den Temperatursensor vorhanden ist, diesen dann bitte eintragen.
Eingabe bestätigen und zum Konfigurationsmenü zurückkehren.
Gerätezuordnung
Gehe zum Abschnitt Gerätezuordnung.
- Die zu steuernden Thermostate hinzufügen