Valves (over_valve)

The over_valve type controls an equipment that can take a value from 0 to 100 %. At 0, heating is off, and at 100 % it is fully open. This type allows controlling a thermostatic valve (e.g., Shelly valve) that exposes a number type entity, enabling direct control of the valve's opening. Versatile Thermostat regulates the room temperature by adjusting the opening percentage, using both the internal and external temperature sensors, and the TPI algorithm.

NOTE

  1. The over_valve type is often confused with the over_climate type equipped with auto-regulation and direct valve control.
  2. You should only choose this type when you do not have an associated climate entity for your TRV in Home Assistant, and if you only have a number type entity to control the valve's opening percentage. The over_climate with auto-regulation on the valve is much more powerful than the over_valve type.

Underlying entities

Only number or input_number entities are accepted as underlying devices. The TPI algorithm recalculates the valve's opening percentage at each cycle and modifies the value of the underlying number entities.

Valve opening control

over_valve can adjust the TPI opening command to match the physical limits of each valve:

  1. opening_threshold_degree: below this raw TPI percentage, the valve is considered closed.
  2. max_closing_degree: maximum closing percentage. The command under the threshold is 100 - max_closing_degree; keep the default 100 to close it fully.
  3. min_opening_degrees: comma-separated minimum opening values, one per underlying valve. A value is applied as soon as the threshold is reached.
  4. max_opening_degrees: comma-separated maximum opening values, one per underlying valve. Omitted values use the maximum supported by the related number entity.

It is possible to choose a thermostat_over_valve to control an air conditioner by checking the "AC Mode" box. In this case, only the cooling mode will be visible.

Sleep mode

over_valve supports sleep mode. Selecting sleep, or calling the versatile_thermostat.set_hvac_mode_sleep action, presents VTherm as off while sending a raw 100 % opening request to every underlying valve. Sleep mode does not request central boiler heating; is_sleeping identifies this state.

See the full over_valve documentation for more details.

Shelly BLU TRV

The Shelly BLU TRV exposes its valve position as a number entity and needs a Shelly BLU gateway. It is partially compatible: some valve commands are lost over Bluetooth, the device has no off mode, and it can become unavailable when the Bluetooth link drops.

Device configuration

Initialization

Go to your settings, then integrations, then click on add a new integration. Search for Versatile Thermostat.

Click on Thermostat over a valve.

Basic attributes

Go to the "Main attributes" section.

  1. Choose a name for your thermostat
  2. Set the temperature sensor for your room
  3. If you are using the Zigbee protocol and you have a "last_seen" entity for your temperature sensor, fill it in.

You can validate and return to the configuration menu.

Underlying entities

Go to the underlying entities section.

  1. Add the valves that will be controlled

You can validate and return to the configuration menu.