Quick start

Heat pump and air conditioning

A heat pump measures the temperature at the indoor unit, often far from the reality of the room. Versatile Thermostat corrects its setpoint with a real sensor and stops it when it's no longer needed.

Versatile Thermostat's strengths

  • Self-regulation

    Versatile Thermostat adjusts the setpoint sent to the heat pump so the room sensor reaches the target temperature. Four levels, from light to expert.

  • Automatic stop and restart

    When the room is at temperature, the heat pump is stopped (or switched to fan or dehumidification) then restarted at the right time: less consumption and noise.

  • Heating and cooling

    The same thermostat heats in winter and cools in summer, with presets dedicated to cooling. Auto-Fan adapts the fan speed.

  • Open windows

    The heat pump stops or switches to fan mode when a window opens.

  • Presence

    Away setpoints apply automatically, for both heating and cooling.

  • Power shedding and central mode

    The heat pump takes part in power shedding. Central mode forces the whole home to heating only or cooling only.

Tutorial: a living room with a Mitsubishi heat pump

Example: a living room cooled by a Mitsubishi air-to-air heat pump integrated via MELCloud, with a temperature sensor placed far from the indoor unit.

  1. Integrate the heat pump

    Add your heat pump's integration (MELCloud, Daikin, SmartIR...) in Home Assistant and check that its climate entity responds.

  2. Install Versatile Thermostat

    Install the integration from HACS, then restart Home Assistant.

    Open your Home Assistant instance and open a repository inside the Home Assistant Community Store.
  3. Create the thermostat

    Add the Versatile Thermostat integration, choose “Thermostat over a climate”, name it “Living room” and select the temperature sensor and the outdoor sensor.

  4. Add the heat pump

    In “Underlyings”, select the heat pump's climate entity and tick cooling mode if it is reversible.

  5. Enable self-regulation

    In “Self-regulation”, choose the light level. It corrects the setpoint sent to the heat pump by up to 1.5 °C.

  6. Enable automatic stop and restart

    Choose the responsiveness (slow for a living room, fast for a small room) and the stop action: turn off, fan only or dehumidification.

  7. Set the presets

    Define the heating temperatures (for example 18 / 20 / 21 °C) and the cooling temperatures (for example 26 / 25 / 24 °C).

Start with light self-regulation and raise the level only if the room doesn't reach its setpoint. Avoid aggressive settings with heat pumps that cut their compressor too often.

Going further

What's next?

Install Versatile Thermostat and find out why it outperforms the alternatives.