Quick start
Thermostatic valve (TRV)
A thermostatic head measures the temperature right next to the radiator, so it regulates poorly. Versatile Thermostat recalibrates it against a real room sensor and can directly control the valve opening.
Versatile Thermostat's strengths
Direct valve control
Versatile Thermostat computes the opening percentage with the TPI algorithm and sends it to the valve, instead of juggling its setpoint.
Room sensor and calibration
The room temperature comes from a real sensor. It can be copied into the valve (calibration offset or external temperature).
Auto-TPI
Regulation coefficients are learned automatically over successive cycles, room by room.
Open windows
Valves close when a window opens, via a sensor or automatic detection of the temperature drop.
Central boiler
The boiler switches on when enough valves call for heat and switches off when all of them are closed.
Several valves per room
A single thermostat controls all the valves in a room, with a minimum and maximum opening per valve.
Tutorial: a living room with two Sonoff TRVZB
Example: a living room heated by two hot-water radiators, each fitted with a Sonoff TRVZB paired through Zigbee2MQTT, and a Zigbee temperature sensor in the middle of the room.
Pair the valves and the sensor
Pair both valves and the sensor in Zigbee2MQTT. Check that each valve exposes the number entities “valve opening degree”, “valve closing degree” and “local temperature calibration”.
Create the thermostat
Settings > Devices & services > Add integration > Versatile Thermostat. Choose “Thermostat over a climate”, name it “Living room” and select the temperature sensor.
Add the valves
In “Underlyings”, add the two valve climate entities.
Enable direct valve control
In “Self-regulation”, choose direct valve control. For each valve, fill in the opening, closing and calibration entities. Leave the TPI coefficients at their defaults: Auto-TPI will tune them.
Set the presets
Define the Eco, Comfort, Boost and Frost protection temperatures, for example 18, 20, 21 and 7 °C.
Windows and boiler
Enable open window detection (sensor or automatic). If a boiler feeds the radiators, declare it in the central configuration so it follows the valves' demand.
With the Sonoff TRVZB, keep a regulation threshold of at least 3%: below that, the valve may lose its calibration. If that happens, use the valve recalibration service.
Going further
What's next?
Install Versatile Thermostat and find out why it outperforms the alternatives.